Special requirements for the main material
|
Signal relays
|
Gold-plated contacts; Use of contact wires; bifurcated contacts; Very small in size, using LCP plastic;
|
Power relays
|
PBT is mostly used in plastics; Pure copper is mostly used for static springs, and copper alloy is used for dynamic springs;
|
Power magnetic latching relays
|
The current is larger, and the reed is thicker;
|
Industrial relays
|
Similar to power relays; Most of the products with larger volume are transparent shells;
|
Automotive relays
|
The load is DC, using AgSnO contacts, and some product dynamic and static contacts are paired with different materials to reduce material transfer; The proportion of coil volume will be relatively large; Grade 180 and above enameled wire;
|
Hermetically sealed relays
|
metal shell, base; glass insulation; Plastic is not used as much as possible; Component links are mostly riveted or welded;
|
High voltage DC relays
|
use of blown magnets; Relay contacts with high currents require a sealing cavity (ceramic or plastic), a copper conductive column;
|