2024-09-11
Categories | Special requirements for the main material |
Signal relays | Gold-plated contacts; Use of contact wires; bifurcated contacts; Very small in size, using LCP plastic; |
Power relays | PBT is mostly used in plastics; Pure copper is mostly used for static springs, and copper alloy is used for dynamic springs; |
Power magnetic latching relays | The current is larger, and the reed is thicker; |
Industrial relays | Similar to power relays; Most of the products with larger volume are transparent shells; |
Automotive relays | The load is DC, using AgSnO contacts, and some product dynamic and static contacts are paired with different materials to reduce material transfer; The proportion of coil volume will be relatively large; Grade 180 and above enameled wire; |
Hermetically sealed relays | metal shell, base; glass insulation; Plastic is not used as much as possible; Component links are mostly riveted or welded; |
High voltage DC relays | use of blown magnets; Relay contacts with high currents require a sealing cavity (ceramic or plastic), a copper conductive column; |